UV MP
The UV MP range has been designed for dechloramination of water in commercial and semi-commercial pools at a flow rate of up to 900 m3/hr. Its medium-pressure lamps completely destroy chloramines present in the water, responsible for skin irritation, and trichloramines present in the air, responsible for eye and respiratory irritation.

Benefits +
- Guaranteed dechloramination: the MP range delivers 60 mJ/cm², even at the end of the lamps’ service life.
- Certification: range approved by the Ministry of Health.
- Touch screen: available on certain models.
- Full parameter display: monitoring of all UV reactor indicators.
- Real-time reading: instant access to operational data
- Multilingual: available in 6 languages
- Quartz sleeve cleaning: manual device as standard, automatic version optional
- Thermal monitoring: temperature sensor in the electrical cabinet and on the reactor (optional)
- Flexible lamp cleaning: available in manual or automatic versions
Certification
EAC
Our system is EAC certified, proving its compliance with the technical standards of the Eurasian Economic Union (EAEU). This marking is mandatory for importation and sale within all EAEU member states
PZH – NIH
The PZH certificate is a Polish Hygiene Certificate issued to products and components that come into contact with water intended for human consumption.
Technical data
| Model | Max flowrate* | Delivered UV doses at indicated UVT / Flow rate ** | UV lamp power | Inlet / Outlet diameter | Reactor length |
| MP030 600W EL | 30 m3/h | 60 mJ/cm2 | 1 x 600 W | DN80 | 488 mm |
| MP030 1kW EL | 40 m3/h | 60 mJ/cm2 | 1 x 1 kW | DN80 | 488 mm |
| MP100 TS | 80 m3/h | 60 mJ/cm2 | 1 x 1 kW | DN125 | 1175 mm |
| MP125 TS | 140 m3/h | 60 mJ/cm2 | 1 x 3 kW | DN150 | 1152 mm |
| MP140 TS | 300 m3/h | 60 mJ/cm2 | 1 x 3 kW | DN200 | 1244 mm |
| MP240 TS | 450 m3/h | 60 mJ/cm2 | 2 x 3 kW | DN250 | 1020 mm |
| MP340 TS | 675 m3/h | 60 mJ/cm2 | 3 x 3 kW | DN300 | 725 mm |
| MP440 TS | 900 m3/h | 60 mJ/cm2 | 4 x 3 kW | DN300 | 824 mm |
** The performance of these devices was calculated at the end of lamp life and with 98% transmittance..